data_APE IF ELITE

Application area

ELISA-IFA

Product line

Automation

APE IF ELITE+portataniche
APE IF ELITE is the latest version of combined ELISA and IFA automated processors of DAS. The instrument is able to manage 10 methods on line with 4 elisa microplates at different temperature; a thre needle system allows fast processing on 16 IFA slides (optional 20 slides). It is equipped with a sliding sample barcode reader; a microplate shaker is also available. All parameter for dilution, dispense, incubation, washing, reading and data processing, are settable.
TECHNICAL FEATURES
ELISA technical features
Liquid handling 2 probes for dilution and dispense of samples and reagents
Sample dispense time
6s (average) with 2ml of washing solution

Sample dilution time 6s (average) with 2ml of washing solution

Plate washing two 8 nozzle manifolds, one to dispense and the other one to aspirate; residual volume <3µl
Plate washing inaccuracy CV <5% at 300µl
Removable tray modular racks to hold calibrators, controls and reagents for 10 methods on line
Microtiter plates 4 standard plates (12 x 8 wells format) independently incubated at room temperature or from 37° to 45° C
Wash buffers

4 wash buffer for microplates in external tanks
Reading system

8 independent photometric channel with mono and bichromatic reading capability
Interferential filters
2 fprecision filters (450 and 630 nm); 2 filters more on request (4 filter max, 400-700 nm)

Reading inaccuracy Reading from 0.000 to 3.000 OD; inaccuracy ±2%
Operative Functions Management of 10 methods in the same run. Definition of incubation times and volume for sample and reagents dispense. Differen incubation times for each method. Easy and fast settings for new protocols. Work list set up, patient reports and result fling. Calibration curve storage for each carried out test
IFA technical features
Liquid handling 3 probes: two to dispense and dilute sample and reagents , the third one to aspirate from wells
Average thoughput
320 wells in a run with incubation times of 30 + 30 minutes

Sample dispense time 6s (average) with 2ml of washing solution
Sample dilution tiem 15s with 2 ml of washing solution
Slide washing Wells are washed one by one to avoid carry-over
Washing mode multi-well, continuous flow or drop by drop for specific washing effectiveness
Supllied trays Tray with 16 position for IFA slides (optional 20 slides); reagent tray for 16 controls, 12 conjugates (11 in case of Blue Evans dye)
Wash buffers 2 wash buffers for slides in external tanks
Operative functions Management of 10 methods in the same run. Definition of incubation times and volume for sample and reagents dispense. Differen incubation times for each method. Easy and fast settings for new protocols. Slide mask, number of wells and thickness for each slide; shape, size and coordinates for each slide well.
maschera vetrini, numero di pozzetti e spessore di ogni vetrino; forma, dimensione e coordinate per ogni pozzetto del vetrino
Caratteristiche tecniche COMUNI
Built-in barcode reader
for sample; barcode reader for slides (optional)

Sample tray
169 sample tubes Ø13mm or 130 sample tubes Ø16mm; combination of them can be used in the same run

Rack diluizioni264 dilution cups
Dilution tray 4 sample diluents on board
DispensationCV <0.1% inaccuracy 1% at 100µl
AspirationCV <0.3% inaccuracy1% at100µl; minimum volume 5µl, resolution 1µl
Syringes2 with 1000µl volume each, 1µl resolution
External liquid tanks

8 external tanks with level sensors
Operative functions Management of 10 methods in the same run. Definition of incubation times and volume for sample and reagents dispense. Differen incubation times for each method. Easy and fast settings for new protocols.
ConnectionsLIS interface capability, work list import from Host Computer; a single PC can run more instrument at the same time.
PCMinimum requirements: 250MB free spache Hard Disk; CD-Rom reader; 2GB RAM; Intel Pentium Dual Core or equivalent; VGA 1024 x 768 x 16 million colours; 1 free USB 2.0 port; printer


Suggestedi requirements: 4GB RAM; Intel Core 2 Duo E6500 series or equivalent

Operative systems Windows 7 or Windows 10
Power requirements 230 o 115 VAC, 50-60 Hz, 650 VA
Measurements 113 x 77 x 75 h
Weight 120 Kg